D-68-12
- 
Model Number: D-68-12 
- 
Rated Power: 67W 
- 
Application: LED, Building access,etc 
- 
Fan Type: Natural cooling 
- 
Name: LED driver power supply 
- 
Input Voltage: 220VAC 
- 
Raw material: 100% brand new 
- 
Dimension: 130x97x38mm 
- 
Packaging Details: - 
- 
Carton Dimention: - 
10 Other Products in the same category
Product Features
*Small size, light weight
*High reliability, low price
*Wide voltage input
*High conversion efficiency, low temperature increase
*Built-in filter circuit, less external radiation interference
*It has a basic protection circuit,good ability to adapt to the environment
*100% full load burn and a full range of functions
Product Details
| Rated output voltage | DC 12V | BAT +13.8V | 
| Output interface position | Six P-9.5mm Terminal Blocks are labeled DC+12V,DC-;BAT+,BAT- | |
| Output voltage range | Setting error ±0.5V | |
| Rated output current | 5A | 0.5A | 
| Floating in current range | 0.5~5A(MAX 5A) | 0.2~0.5A(MAX 0.5A) | 
| Output voltage ripple | Vp-pmax<120mV | Vp-pmax<138mV | 
| Li; Lo regulation | Line:±0.5%;Load:±0.5% | Line:±1%;Load:±15%(BAT±3%) | 
| Comprehensive regulation accuracy | ±1% | ±16%(BAT±4%) | 
| Rated output power | 67W | |
| Rated working efficiency | >=70% Output power rating | |
| Rated input voltage | Rated voltage:AC220V Operating voltage:AC176~264V interface position AC-L,AC-N,FG | |
| Rated input current | Rated current AC0.6A,current range AC0.2~1A | |
| AC input frequency | Rated AC voltage frequency range 47 ~ 63Hz Sine wave | |
| Input inrush current | Working energized instant impact on the power grid surge current,Boot cold start maximum of 60A / 10mS | |
| Input Overvoltage Protection | ------ | |
| Output overload protection | Overload protection point of about 120% to 200% of rated output power | |
| Output overvoltage protection | ------ | |
| Work overheating protection | ------ | |
| UPS battery management | Need an external battery (capacity 3-6AH) as a backup power supply,when the AC power supply is stopped converted to a backup power system automatically,System Conversion <= 50mS,when AC power supply become normal then AC power supply and battery management automatically | |
| Power time parameter | Preparation time (SETUP TIME) ≈200mS;Settling time (RISE TIME) ≈50mS;Hold time (HOLD UP TIME) ≈20mS | |
| Dielectric strength parameters | The input - output terminals:> AC1.5KV, inputs - Housing: AC1.5KV, the output terminal - Housing:> AC0.5KV leakage current <5mA 50Hz 1min | |
| Operating temperature parameters | Working temperature drift coefficient is about ± 0.03 [% / ℃]; absolute temperature coefficient of about 0.50 [℃ / W]; rated power output at work, body absolute temperature rise of 25 ℃ ± 5 ℃ | |
| Environmental conditions parameters | Storage environment: -20 ℃ ~ + 85 ℃; 10% ~ 95% RH .. Working environment: -10 ℃ ~ + 50 ℃; 20% ~ 90% RH .. (Depending on the environment and the power) | |
| Work cooling mode | Designed for continuous work standard, natural cooling heat ( the using environment and its mounting position have an effect on power usage) | |
| Exterior dimensions | Size: L130 × W98 × H37mm3; dimensions: L52 × W31mm2, L125 × W10mm2 | |
| Net weight and external color | Weighing about 416g; Bottom is 1.2mm thick aluminum, sand silver oxide surface treatment; cover shell is 0.5mm thick iron, silver plating surface treatment | |
| Design criteria based on | GB GB-4943 | |
| Note: 1) the over detection indicators are measured under the following conditions:within the range rated input voltage and rated output load ,environment is 25 ℃, 85% RH,no wind 2) output DC voltage ripple detection:With a length of 30cm 1mm2 cross section one end is 0.1μF and 0.47μF bypass capacitor in parallel twisted wire detection points were detected 100Hz Frequency ripple maximum peak Vp-p100Hz and integrated ripple maximum peak Vp-pmax 3) Li voltage regulation: a load of ratings,Input voltage fluctuation in the nominal range ;Lo Load Regulation: the rated input voltage and load variations from zero to rated. | ||